IO port register sizing and how device recognise address is for it - io

I read in a article about that 64k io port each are address assigned to 8bit register and when you combine io port together you get 16 bit,32bit etc. Sorry i am not getting that website in my history now so i cant provide link.
I just not understood what it want to say so i just put the raw form here
So there are mine few points that i want confirmation on as i am confused bcoz as i accidently land on another website they have just another idea.
i) i/o ports are assigned to registers of peripherals. These are of 16bit as there are 64k port and register they are assigned to can be of any size(8,16,32,64bit).
ii)Except for pci related devices io port address number are fixed,but as in device with configuration space register can be assigned io address number using bar any number one want just i should not be used by anyother device.
Que1)When a address come out of processor it goes to motherboard through northbridge/system_agent and it routes it according to address map it has, peripheral device are told to accept i/o range or memory address range on basis of what was configured in bar,but as northbridge is made up of many controller [like memory,graphics,pci etc] but it is who, who has address mapping to route.
queii) according to intel 82815 gmch northbridge page 129 section 4.3
"The processor allows 64K+3 bytes to be addressed within the I/O
space. The GMCH propagates the processor I/O address without any
translation on to the destination bus"
What does this means it only routes mmio and io bar but than how rest of io address(that are not assigned by software or due to i/o bar register) are decided. where should they go how peripheral device know this address it should acccept,if they are just thrown on the bus than how CS pin is decided of particular device

Related

Thread Networks: why have a Full End Device?

The Thread Specification defines two types of devices with their respective sub-types:
Full Thread Devices (FTD)
1.1. Router
1.2. Router Elegible End Device (REED)
1.3. Full End Device (FED)
Minimal Thread Devices (MTD)
2.1. Minimal End Device (MED)
2.2. Sleepy End Device (SED)
2.3. Synchronized Sleepy End Device (SSED)
From my understanding of the specification, a FED cannot forward messages and is not capable of becoming a Router. This sounds to me like a power-hungry MTD, since it has its radio always on.
Then why does it even exist?
openthread.io has a good definition of the differences between FED & MTD:
A Full Thread Device (FTD) always has its radio on, subscribes to the all-routers multicast address, and maintains IPv6 address mappings...Full End Device (FED) — cannot be promoted to a Router
A Minimal Thread Device does not subscribe to the all-routers multicast address and forwards all messages to its Parent...Minimal End Device (MED) — transceiver always on, does not need to poll for messages from its parent
An MTD saves power compared to an FTD at the expense of some functionality. Being a router or router-eligible requires more RAM. So if you have an always-on and line powered device but need to save RAM (or don't have any to spare,) it makes sense to configure it as a FED.

Gigabit Ethernet takes ~370ms to report link down in MII register

To give you some context, I am trying to configure some network redundancy on Ubuntu 20.04.
I decided to use NIC bonding with:
2 Gigabit interfaces,
active-backup mode,
link state monitoring with MII (polling every 10ms).
It works as expected, when the active slave fails (wire unplugged) the bonding switches to the other slave. However this transition is too slow in my opinion as it takes up to 400ms.
In order to investigate I had a look at the MII register using this command: mii-tool -vv ens33 (-vv is to print raw MII registers content). It generates this kind of output:
Doing a basic bash script I print current time + value of the 2nd MII register which contains the link state. As this is a "while true" loop with no pause, I get a status every 20ms, so it allows me monitoring with enough reactivity.
Observed behavior:
when the interfaces are configured with a 100Mbit/s speed, Full Duplex => the MII register is almost immediately updated (no "visible" delay between the wire unplugging and the update of the register value on the screen).
however when configured at 1Gbit/s, Full Duplex (via auto-negotiation) => the update of MII register takes much more time (it is "visible" with the bash script). By sending pings every 10ms using the bond interface, and logging packets with Wireshark on receiver side, the observed delay is around 370ms.
My questions:
The Ethernet controler is an Intel I210, and I have not found anything relevant in the datasheet.
Do you see any reason for such a long time to detect link down when interface speed is 1Gbit/s vs 100Mbit/s (370 vs 50ms) ?
Any advice to improve the reactivity?
Thanks for your help :)
Every generation of Ethernet speed has it's own method and requirements.
10BaseT:
"link pulses" are used every 16 ±8 ms
100BaseT: "link pulses" are not used but Idle ("/I/") 4B/5B code words monitoring is instead.
1000BaseT: link failure is actually
determined by maxwait_timer which is defined in IEEE 802.3 to be 750 ±10 ms for Master and 350 ±10
ms for Slave ports.
As you can see, your measured 370ms are exactly what you can expect from a slave port.
Sources:
https://www.microchip.com/forums/FindPost/417307
https://ww1.microchip.com/downloads/en/Appnotes/VPPD-03240.pdf

how to find out which ioports be assigned to my devices

has linux reserved io port numbers for all manufactured devices.
I have devices like intel built-in network card. or another device I have for wifi (usb) from realtek.
On linux repository on github, device drivers use specific io ports to register. And kernel assign those ports to device driver. device drivers normally request for ports using call to request_region function. so for some ethernet device it requests like following
for (id_port = 0x110 ; id_port < 0x200; id_port += 0x10)
{
if (!request_region(id_port, 1, "3c509-control"))
continue;
outb(0x00, id_port);
outb(0xff, id_port);
if (inb(id_port) & 0x01)
break;
else
release_region(id_port, 1);
}
above starts with 0x110 to 0x200, any port can be assigned in this range by kernel to driver and appear in /proc/ioports file means driver is using that io port by the time of success return from request_region.
Question : So my question is has linux assigned io ports to all manufactured devices usable with kernel 5.7 or latest kernel version?
Question : What if I want to write device driver for any device. How can I find the io ports number range to request to. I dont not expect that I have to look into kernel code and find similer driver port range. so How can I find that io port number range. how to achieve this first step required in writing device driver (any device. be it wifi internet device or ethernet device)
Question : So my question is has linux assigned io ports to all manufactured devices usable with kernel 5.7 or latest kernel version?
No.
Question : What if I want to write device driver for any device. How can I find the io ports number range to request to.
You ask the user for it. After all it's the user who set them using jumpers on the ISA card.
Here's a picture of an old Sound Blaster card (taken from Wikipedia, I'm too lazy to rummage around in my basement now). I've highlighted a specific area in the picture:
That jumper header I highlighted: That's the port configuration jumper. As a user you literally connect two of the pins with a jumper connector and that connects a specific address line that comes from the card connectors to the circuitry on the rest of the card. This address line is part of the AT bus port I/O scheme. The user sets this jumper, writes down the number and then tells the driver, which number it was set to. That's how AT style I/O ports.
Or the driver uses one of the well known port numbers for specific hardware (like network controllers) that dates back to the era, where ISA style ports were still are thing. Also there's old ISA-P'n'P where the BIOS and the add-in cards would negotiate the port assignments at power up, before the OS even started. You can read those port numbers with the ISA-P'n'P API provided by the kernel.
We no longer use this kind of hardware in practice! Except for legacy and retro computing purposes.
Over a quarter of century ago, the old AT / ISA bus was superseeded with PCI. Today we use PCIe which, from the point of view of software still looks like PCI. One of the important things about PCI was, that it completely dropped the whole concept of ports.
With ISA what you had were 8 data lines and 16 address lines, plus two read/write enable lines, one for memory mapped I/O and one for port I/O. You can find the details here https://archive.is/3jjZj. But what happens when you're reading from say, port 0x0104, it would physically set the bit pattern of 0x0104 to the address lines on the ISA bus, pull low the read enable line, and then read the voltage level on the data lines. And all of that is implemented as an actual set of instructions of the x86: https://c9x.me/x86/html/file_module_x86_id_139.html
Now look at the PCI bus: There's no longer separate data and address lines. Instead read/write commands would be sent, and everything happens through memory mappings. PCI devices have something called a BAR: a Base Address Register. This is configured by the PCI root complex and assigns the hardware the region of actual physical bus addresses where it appears. The OS has to get those BAR information from the PCI root complex. The driver uses the PCI IDs to have the hardware discovered and the BAR information told to it. It can then do memory reads/writes to talk to the hardware. No I/O ports involved. And that is just the lowest level. USB and Ethernet happen a lot further up. USB is quite abstract, as is Ethernet.
Your other question Looking for driver developer datasheet of Intel(R) Core(TM) i5-2450M CPU # 2.50GHz suggests, that you have some serious misconceptions of what is actually going on. You were asking about USB devices, and Ethernet ports. Neither of those in any way directly interact with this part of the computer.
Your question per se is interesting. But we're also running into a massive XYZ problem here; it's worse than an XY problem; you're asking about X, although you want to solve Y. But Y isn't even the problem you're dealing with in the first place.
You're obviously smart, and curious, and I applaud that. But I have to tell you, that you've to backtrack quite a bit, to clear up some of the misconceptions you have.

How are MMIO, IO and PCI configuration request routed and handled by the OS in a NUMA system?

TL;DR
How are MMIO, IO and PCI configuration requests routed to the right node in a NUMA system?
Each node has a "routing table" but I'm under the impression that the OS is supposed to be unaware of it.
How can an OS remap devices if it cannot change the "routing table"?
For a proper introduction to the "routing table", i.e. the Source Address Decoders (SADs), refer to Physical Address Decoding in Intel Xeon
v3/v4 CPUs: A Supplemental Datasheet.
I'll first try to recap what I've gather from papers and barely documented datasheets. Unfortunately this will longer the question and may not have all the pieces.
When a request egress the LLC1 the uncore need to known where to route it.
On the workstation CPUs the targets are either the DRAM, one the PCIe root port/integrated device or the DMI interface.
The uncore can easily tell if a memory request belongs to the DRAM thanks to the iMC registers2 or to one of the PCIe root port3/integrated device and will eventually fallback to DMI.
This, of course, also include MMIO and is almost identical for port mapped IO (which only skips the DRAM check).
PCI configuration requests (CFG) are routed as per specification with the only caveat that CFG requests on bus 0, not targeting the integrated devices, are sent down the DMI interface4.
On a server CPU the target of physical address can be off-socket.
A table is used to look up a node id (NID)5. This table is called the SAD.
Actually, the SAD is made of two decoders: the DRAM decoder (which uses a table) and the IO decoder6 (which is made of mostly fixed ranges and enable bits but also should contains tables).
The IO decoder overrides the DRAM decoder if needed.
The DRAM decoder work with a list of ranges, each associated with a list of target NIDs7.
If a memory, MMIO or PCIe memory-mapped configuration request (MMCFG) matches a range, the uncore will send the request along the QPI/UPI path to the selected target (it's unclear if the SAD can target the requestor node itself).
The IO decoder work either with enable bits for fixed ranges with fixed targets (e.g. reclaim the legacy BIOS windows to the "BIOS NID") or with variable range where part of the address is used to index a list of targets.
The port mapped IO destinations are looked up in a table depicted as IO[yyy].
The MMCFG IO destinations are looked up in a table named PCI[zzz].
The CFG destinations reuse the PCI[zzz] table.
Here yyy and zzz denote the index function, i.e. a part of the request address ( zzz is the bus number for CFG).
All this makes sense to me but these tables are not documented in the datasheet so a symbol like PCI[zzz] may actually means something entirely different.
While there is little to no documentation on these decoders, it's enough for a primitive mental model.
It is still not clear to me if the SAD are used even for requests that target the local resources or if they are used only for egressing requests.
This will be important later.
Let's say that when a request leaves the LLC the SADs are used to route it to a component (eventually in the same socket) and then it is handled similarly to the workstation case8.
As long as the hardware configuration isn't changed the SAD can be configured by the firmware and the OS can be totally agnostic of them.
But what happens if the OS remap a PCIe device that is behind a node's local PCIe link?
For a MMIO request to reach such a device it must first reach the device's node (since it is the only link with the rest of the system) but this can only happen if the SADs are properly reconfigured.
Reconfiguring of the SADs may be required even for requests originating from the same node as the device9.
But the OS is supposed to be unaware of the SAD, or isn't it?
I have a few possible answers:
The SAD are not used for accessing local resources and the OS restrict access to local IO only to processes (or the kernel) running in the parent node. This avoid the need to reconfigure the SADs.
The firmware configure the SADs so that each node has a portion of the address space (say 2k / N, where k is size of the physical address space and N is the number of node) and report that in the SRAT ACPI table. (but isn't the SRAT optional?)10 The OS then allocates MMIO resources only within each node memory portion. This may lead to suboptimal memory use.
The SADs are an optimisation, if the uncore don't know where to route a request it will pass it to the QPI/UPI link(s) until it is sinked by a node.
Everything above is wrong.
1 e.g. due to a miss or due to being UC.
2 e.g TOUM for the maximum physical address reclaimable by the DRAM, though it's not a continuous block.
3 Which are PCI-to-PCI (P2P) bridge and have the registers to set the IO, prefetchable and non-prefetchable memory windows.
4 That's why PCH devices appears on bus 0. Server CPU have two "internal" busses and their numbers can be changed.
5 A node id is made of a socket number and an uncore component id. The uncore component I'm aware of that can be targets are (after name translation from the "box" nomenclature): The first or second Home agent (iMC), the System agent and the DMI link.
6 The IO decoder table is split into IOS (IO Small decoder) and IOL (IO Large decoder). This reflects the hardware capability of the two tables, with the IOS being almost fixed and the IOL being a CAM. Both are consulted in parallel with the DRAM table, the IOS overrides the IOL if both matches.
7 The range is automatically interleaved (i.e. sub partitioned) between all of the eight targets. To use less than eight targets, duplicate entries can be used (e.g. all set to the same targets is the same as no interleaving).
8 I wonder what happens if the SADs route a request to an uncore component (say the iMC) but outside its reclaimed range? I guess it is discarded.
9 See bold part above, I don't know how the SAD work with requests targeting local resources.
10 Linux fake a NUMA node in UMA machines. In my box the quantity of memory allocated to the node includes MMIO (almost 10GiB allocated vs 8GiB or DRAM). It seems the whole range returned by the E8020 is used.
This answer uses elements from the the Xeon 5500 and 7500 datasheets (which use a ring and an Rbox to connect to the rest of the system), but this answer speaks about a system whose ring bus architecture resembles the IvB-EX Xeon e7 v2 (which uses 2 rings) but also applies to Haswell-EX (which uses 4 rings with an interconnect between the 2) SnB and Broadwell. I presume each ring is still split into 4 32 byte bidirectional rings: snoop/invalidate, data/block, request/address, acknowledge rings.
Xeon e7 v2:
On the falling edge of the reset signal, the package instantly determines the NodeID and adjacent NodeIDs, x2APIC cluster ID and logical processor APIC IDs (before SnB on desktop CPUs it used to sample MCH signals on input pins to do this; I'm not sure about multisocket since SnB). After this, the caches and TLBs are flushed, cores perform BISTs and then a multisocket MP initialisation algorithm occurs. Xeon D-1500 vol2 shows a CPUNODEID register; I'm not sure what sort of behaviour arises when changing that post-reset regarding in-flight transactions. Are SAD target lists changed via automatically generated writes when CPUNODEID changes on other cores, or does it trigger SMI handler or is this the task of the programmer? IDK. Presumably, all agents would have to be Quiesced to stop them accessing the Cbo before the SAD config can be changed.
Caching Agent
Each socket has a caching agent and a home agent (or 2 CAs and 2 HAs on MCC/HCC). The functionality of the caching agent is address-hashed across Cbo slices (before SnB, the caching agent was the combination of the Sbox and the 50% of Cboxes that were associated with it, where the Sbox was the QPI interface that picked up Cbox messages from the ring and converted them to QPI messages directly to the Rbox, and the Cbox was the interface between the LLC slice and the ring bus; after SnB, the Cbo implements the functionality of the Sbox and the Cbox on and sends QPI/IDI messages one ring interface). The mapping is set at boot time because that’s when the snooping mode is set. On Haswell-EX, the snoop mode can be toggled in the BIOS between no snoop, home snoop, early snoop, source snoop, HS w. Directory + OSB + HitME cache or COD, depending on the CPU; although I am yet to see any datasheet with PCIe configuration registers related to snoop modes. I'm not sure what behaviour arises for in-flight transactions when this is changed post-reset. When a core is disabled by BIOS, it does not impact the Cbos, which continue to function. The Caching Agent was a separate component on Nehalem-EX (see 7500 datasheet), but on later architectures it is used to refer to the Cbos as a whole. COD (Cluster on Die) introduced on Haswell-EP splits the caching agent into 2 per socket
CBo
Within each cache slice there is a cache box which is a controller and an agent between the LLC and the rest of the system, basically the LLC controller. The Cbo contains the Table Of Requests that holds all pending transactions. The Cbo supports three types of transactions: 1. Core/IIO initiated requests 2. Intel QPI external snoops 3. LLC capacity eviction. Each transaction has an associated entry in the TOR. The TOR entry holds information required by the Cbo to uniquely identify the request (e.g. address and transaction type) and state elements required to track the current status of the transaction.
Core/PCIe requests are address hashed to select a Cbo to translate and place the request onto the ring. The core knows what direction on the ring to send the request for smallest latency so it would be configured with the same address map and it waits for a vacancy on the ring to accommodate the transaction.
Core originated requests use the IDI packet interface. IDI (Intra-Die-Interconnect) is shown on Broadwell-EX. The diagram implies cores only use IDI packets and CBos use QPI and IDI. Xeon e7 v2 opcodes are shown on Table 2-18 and QPI opcodes on Table 2-218. This also prevents something like IIO claiming an address before it is decoded, because it only accepts QPI opcode. On some diagrams, Ubox is pictured to share a stop with IIO; on others they are separate.
When the vacancy arrives, the bidirectional stop logic it shares with the Cbo will place the 32 byte flit into the request ring and if the Cbo needs to send to the same direction at the same time then the transaction with a target that will be in correct polarity at the target is selected, otherwise some other form of arbitration is used. I presume the core can write to both directions in the cycle and the Cbo on the stop can read from both, or the Cbo and Core can write one and read one depending on the arbitration. I would imagine the link layer header of the IDI flit contains source, dest IDs allowing for a higher layer transaction (transport layer) to be split up and arrive non-contiguously as and when free gaps on the ring appear and so it knows whether to continue buffering the transaction and remove the flit from the ring. (Ring IDI/QPI is different to QPI which doesn't have link layer source/dest, because QPI is point to point; also QPI only has a 80 bit flit which is easy to find a diagram of; not the case for ring bus headers). The Cbo implements the QPI link layer credit/debit scheme per destination to stop buffer overflows. This request probably will only need 1 flit but cache line fetches would need 3. Cbo decodes when it sees the relevant opcode and address in the address range it has been assigned. Now it has to decode the address to see what to do with it.
Within the Cbo, requests go through the SAD at the same time that they are allocating into the TOR and are sent to the LLC. Non-LLC message class types go through the SAD when they are allocating into the TOR as well. The SAD receives the address, the address space, opcode, and a few other transaction details. To help reduce the number of decoder entries required for the varying DRAM capacities, the address decoder has several interleave options and on the Xeon 7500 is divided into 3 decoders with priority highest to lowest: I/O small (IOS) decoder, I/O large (IOL) decoder, DRAM decoder. On the Xeon e7 v2, there are 4 decoders: DRAM, MMIO, Interleave, legacy.
Each of these decoders is presented with an address and accessed in parallel. Addresses that match an entry in one of the decoders cause the decoder to lookup and generate the QPI memory attribute and NodeID. Only one match is allowed per decoder. Address matches in a higher-priority decoder will override simultaneous matches in lower-priority decoders.
I/O Decoders
There are 8 target list presented here, PCI[], MIOU[], MIOL[], FWH[], APIC[], IOH[], CPU[], IO[]. These, along with some I/O decoder entries are configurable via CSRs under the Cbo device, and each Cbo has its own SAD. The Local Cfg registers, which is just a fixed MMIO region that maps the local PCIe configuration registers only has one target, the local socket, and doesn't need any target list (it's always going to be routed to the Ubox, so the NodeID will be that of the local Ubox on 7500).
Intel Xeon processor E7 v2 product family implements 4-bits of NodeID (NID). Intel Xeon processor E7 v2 product family can support up to 2 HAs in each socket. The HAs in the same socket will be differentiated by NID[2]. In cases where the target is only 3 bits, NID[2] is assumed to be zero. Therefore, the socket ID will be NID[3,1:0]. The Intel® Xeon® processor 7500 series implements 5 bits and can support up to four sockets (chosen by NID[3:2] when NID[4] is zero). Within each socket are four devices (NID[1:0]): Intel® 7500 chipset (00), B0/S0 (01), Ubox (10), B1/S1 (11). B0/S0 and B1/S1 are two sets of HAs (Bboxes) and CAs (Sboxes).
E7 v2 has 4 bits of NodeID meaning it could support up to 8 sockets and 2 HAs per socket. If a socket has 2 HAs (MCC, HCC) it will still have 2 separate NodeIDs for each regardless of whether it is in COD mode or not and cache and DRAM locality can still be exploited by NUMA aware applications using the hemisphere bit as CBos are always associated with the HA in their socket half (hemisphere) by a hash algorithm. The hash function for instance might cause addr[6] to select a CBo hemisphere in the core and depending on how many (n) CBos are in the hemisphere, addr[x:7] mod n selects the CBo. Each CBo handles a particular range of LLC sets, where the socket's LLC cache covers the entire address range. COD instead creates 2 cache affinity domains (where the CBos in either hemisphere now each cover the full address range instead of half of the address range and therefore become their own official NUMA nodes with a fully spanning cache (rather than 2 NUCA caches) like it's its own socket -- core cache accesses will now never travel across to the other half of the socket, reducing latency, but reducing hit rate as the cache is now half the size -- you can still get this same level of cache latency and more capacity with COD off if you access only the memory associated with the NUCA/NUMA node). The HA that is associated with the CBo hemisphere is also the HA that the CBo uses for DRAM accesses if the DRAM access is local to the socket, because addr[6] is used to select a HA in the DRAM decoder. When there are multiple sockets, addr[8:6] selects a HA, which may be on another socket, so it will use the CBos in the half of addr[6], but the CBo will send the LLC miss to a home agent on another socket if `addr[8:7] of the home agent they are associated with isn't used, if the NUMA scheduler cannot 'affinitise' the process and the memory properly.
This is a paraphrasis of the I/O Decoders' list it appears. The table includes the IOS and the IOL decoder entries. The attribute, e.g. CFG, is the output opcode class from which an opcode will be selected.
DRAM Decoder
On the Xeon 7500, the DRAM decoder is composed of two arrays, a CAM array and a payload array. The DRAM decoder has 20 entries in each array for 20 different regions of minimum 256MiB with 8 sub-regions (interleaves). DRAM decoder
entries can also be used to define coherent, MMIO, MMCG and NXM spaces. If more than one PCI segment is required, DRAM decoder entries are used to configure it above the top of DRAM but unlike the normal PCIe entry below 4G, these entries should not be interleaved, so multiple targets will require multiple SAD entries, and would need to put these same SAD entries into every socket. The CAM array has special compare logic to compute whether an address is less than or equal to the region limit of each entry, to allow for any region size that is a multiple of 256 MiB. The region limit address bits [43:28] are stored in the CAM array of the entry (meaning 256MiB granularity). The payload array (tgtlist–attr) has 42 bits per entry.
You'd expect to see 20 64 bit (6 bits reserved) configuration registers for these SAD DRAM decoder entries (and there appears to be only one set of SAD rules that all the SADs on the socket use), although this is for 5500, and I think there is still only one set of registers for all the CBo SADs on newer CPUs.
On 5500, you set the PA[39:26] for the rule in [19:6] and the method of index generation in SAD_DRAM_RULE_0 and then in SAD_INTERLEAVE_LIST_0 you put the target list -- this sets the decoder fields and presumably the others are set. There must be a register to set the hemisphere bit for the entry (but it's not shown on the datasheet), which tells it to xor the first bit of the NID in the list with the CboxID[2] (what HA it belongs to -- same as NID[1] of current Cbox's HA i.e. addr[6]) of the current Cbox. The idea is that NID1 is always made to be 0 in the target list, such that the xor with the current Cbox's CboxID[2] causes it to select the home agent that belongs to the Cbox (which is why you don't need SAD entries for each individual CBox).
The target list entries are 2 bits on the Xeon 5500 Nehalem-EP (Gainestown), which is of the DP (Dual Processor) Server line, so max is only 2 sockets (only has 2 QPI links, one for IOH one for inter-CPU), hence a max of 4 HAs. It will be 3 bits on the 7500 (4x QPI) (4 sockets with 2HAs each: 8HAs), which expand to 4 bits to include a redundant NID[4]. SAD and DRAM decode entry configuration would surely have to be set identically across all sockets.
Interleaving for 8 nodes (HAs) is done on addr[8:6] of the address and these are removed (excluded) from the address sent to the target HA as it knows its own ID. The above table is for 7500, where addr[6] identifies the HA (NodeID[1]) on the socket.
There are 2 types of requests:
Non Coherent requests
Non-coherent requests are either data accesses that map to non-coherent address space (like MMIO) or they are non-memory requests like IO read/write, interrupts/events, etc. When NC requests access NC memory, they are sent to the Cbo according to the hash of the address just like coherent requests. The NC requests which do not target memory are sent to the Cbo that is attached to the core which generates the request.
MMIO
A transaction relating to a specific address is received by the Cbo is put through the I/O and DRAM decoder, stored in TOR but not sent to the LLC slice if the IDI opcode is uncacheable (e.g. PRd) which the core sends depending on memory type in PAT/MTRR read on L1 access, except for WCiL, which invalidates aliases in other cores and caching agents I think. It will match in the I/O decoder entry for one of the MMIO regions. There will be 8 IOAPICs on some CPUs (not on Xeon 7500 because it talks about ICH/IOH and it's Beckton (Nehalem-EX), so this is the very first implementation of the ringbus; but when the PCH was introduced on Nehalem Ibex Peak, it got integrated on chip in the IIO module). The yyy in FECX_(yyyx)XXXh (so bit [15:13]) will be used to index into the APIC[] table for the NodeID. This means there is 8KiB per IOAPIC in a 64KiB contiguous region. The SAD outputs the NodeID and the opcode to use (NcRd). Xeon 3400 manual talks about 'node Id' being assigned to IIO, maybe this is the 'chipset/IOH' node ID, but E7 v2 doesn't have this, so perhaps there is a hidden extension to select between IIO and Ubox or maybe there's a separate ID appended to the QPI request and Cbos also have an ID. IIO will then route the MMIO access based on integrated IIO and PCI bridge registers and subtractively decodes to DMI.
Also, there are 2 Regions MMIOL and MMIOH for MMIO BARs. There is 256MiB of MMIOLL interleaved for a maximum of the last 7 sockets and 256MiB of MMIOLU for a max of the first 7 sockets, depending on the value of PCIEXBAR (if PCIEXBAR is at 2GiB then MMIOLL won't exist). 7500 datasheet says the MMIOH requires separate I/O decoder entries per socket.
The general server CPU memory layout is like this:
There is a SCA_PCIE subregion that occupies the first 8MiB of the 256MiB configuration space which must be in a 256MiB region below 4GiB. When the address in the transaction is in the local clump address range (1MiB clump per socket), then the normal PCIe decoding is overridden and the NodeID is taken as PhysicalAddr[22:20]. Notice that 1MiB is Bus 0 (32 dev * 8 func) -- bus 0 of all sockets are visible to all other sockets. The NodeID will then be put in a QPI transaction with NcCfgRd opcode and NodeID destination and the flits are placed on the request ring; this will then be absorbed by the QPI link that recognises that NID range and once on the target socket, it will be routed to the Ubox (on SnB, IIO appears to handle NcCfg requests according to Xeon 3400 vol2 5.8.1) which will perform the configuration read; the Ubox has a unique NodeID on the 7500, so it will be routed to it seamlessly (on e7 v2 we assume that there is a hidden ID for these inserted in the packet). In the QPI packet the Cbo maybe inserts a requestor NodeID, a requestor CBo ID and transaction ID; the Ubox buffers and tracks the transaction (I assume sends an acknowledge back on the acknowledge ring) and will send back the results (success/failure) to the source NodeID in QPI packet on the data ring once the processing has finished and it will travel back over the the QPI link. The CBo completes the transaction and returns an IDI packet to the Core on the data ring.
If the address falls outside of the 8MiB region but is in the 256 PCIe configuration space then it will match the top entry in the I/O decoders list. The zzz bits (clearly bit 27-25) is used to index into the target list to select a node. We know that that's clearly the top 3 bits of the bus number. This has to suggest that, assuming index = socket no in interleave list, socket 0 allocation would start at bus 8 (with bus 0 as bus 0) socket 1 would start as bus 32 (with bus 0 as bus 1), socket 2 at bus 64 (with bus 0 as bus 2), socket 3 at 96 (with bus 0 at bus 3) (and in the request sent to socket 3, I assume it removes the NodeID bits such that it would see bus 1 and not 96 (or perhaps bus 0 if it aliases rather than adding 1)). Accessing from this PCIEXBAR config space limits the number of buses in a segment to 32, so full 256MiB aliases dedicated to a each segment need to be assigned (in the DRAM decoder you can set a MMCFG entry targeting a particular socket by presumably setting the target list to contain only a NodeID on the socket) and any access to this range is directed to that socket. PCI[zzz] seems to mean: index into the PCI target list to select a NodeID and give the request an opcode of the attribute class (NcCfgRd/Wr based on TOR details), the Cbo also translates the address to a bus/device/function no. The BIOS would have to read this configuration register in order to enter the correct subordinate device numbers for the PCI-to-PCI bridges on PCIe ports.
On the I/O decoder there are also the entries LclCSRs (Local Config), Glb IOH CSRs (IOH Cfg), Glbl CPU CSRs (CPU Cfg), lcl clump CSRs (Local clump CPU Config). These are fixed MMIO aliases of accessing the PCIe Configuration Space Registers (CSRs) without using PCIEXBAR.
IO
All sockets have IO ports that are fixed and ones that can be set in BARs with Memory Space Indicator set to IO space.
The IO request is received by the Cbo and it is looked up in the IO Table. There doesn't seem to be a separate IO opcode on the IDI list, neither an UC write counterpart of PRd, there might be an undocumented one, or it encodes it in WCiL.
The IO request can either be IO-PCIE or IO-SCA or Non-PCIe-IO. If the address matches the pattern in the bottom row and an IO bit is set and the address is CF8/CFC then 4 zeros are inserted into the address [11:8] (the core can only issue 8 bits of register index), making the CONFIG_ADDRESS function number LSB start at bit 12 rather than 8 and the bus number MSB is at bit 27 and it is now compared to the 3rd bottom row. If The top 5 bus bits match, then the NodeID is determined by [22:20], and an NcCfgRd/Wr is sent to that NodeID. If it is not CF8/CFC then the destination NodeID is determined by looking up a target list entry using IO_Addr[15:13] – so the 3 most significant bits of the IO port. This means that each socket has 8KiB of I/O space, and variable I/O will have to be set in the range for the socket. For fixed I/O accesses, if you make the top 3 bits that of the socket then theoretically they could be removed by the Cbo on the match; so in order to access 20h on socket 1, you'd use 2020h.
Other
Core issued requests which can match decoder entries by opcode are: • IntA, Lock, SplitLock, Unlock, SpCyc, DbgWr, IntPriUp, IntLog, IntPhy, EOI, FERR, Quiesce. The are allocated in the TOR but not sent to the LLC. SplitLock is used when a hardware lock operation crosses 2 cache lines. Lock used to be directed by the Cbo to the Ubox to quiesce all agents to perform an atomic operation but that is unnecessary overhead as it can be implemented in the cache coherence protocol. So either Lock RFO is now picked up by the Cbo and it invalidates other copies and responds and the core can’t read the line until then (presumably there is an indicator in the LLC that the line is locked in the core indicated in the snoop filter).
Coherent requests
Coherent requests are requests to access a memory address that is mapped to the coherent address space. They are usually used to transfer data at a cache line granularity and/or to change the state of a cache line. The most common coherent requests are Data and Code reads, RFOs, ItoMs and Writeback Evictions (WbMtoI) / Writebacks (WbMtoE) to LLC (inclusive cache only). The Coherent requests are serviced by the Cbo that holds the LLC slice for the specified address, determined by the hashing function.
If the address decodes to a DRAM region and the last level cache slice attached to that Cbo indicates that a core within the socket owns the line (for a coherent read), the Cbo snoops the request to that local core (this is obviously talking about an inclusive L3 with snoop filter bits in the the LLC slice by accesses from other cores; note that on SKL server mesh interconnect (not desktop as it still uses ring), the L3 is non-inclusive; in an inclusive cache, if it is valid in 2 cores then the LLC copy is valid).
If the line isn't in the cache (assume COD/HS mode w. Directory (ecc) + OSB + HitME cache is being used), then the caching agent that requests a cache line does not broadcast snoops. Instead it forwards the request in QPI to the HA NodeID that owns the address based on the SAD decoder rules, which then sends snoops to other caching agents which might own the line. The forwarding to the home node adds latency. However, the HA can implement a directory in the ECC bits of DRAM to improve performance. The directory is used to filter snoops to remote sockets or node controllers; on successful snoop response it will allocate an entry in the directory cache. The directory encodes 3 states: not present in any node, modified in 1 node (writeback and downgrade required, and the bit probably indicates which half of the nodes it is in for a targeted broadcast), shared in multiple nodes (meaning that snoops aren't required); If a directory is not supported, I assume it has to snoop all sockets on every DRAM access, while the access is taking place. Haswell-EP also includes directory caches (HitMe) to accelerate the directory lookup. However, with only 14 KiB per HA these caches are very small. Therefore, only cache lines that are frequently transferred between nodes are stored in the HitMe cache. The directory cache stores 8-bit vectors that indicate which of 8 nodes (there are up to 3*2 logical COD nodes on Haswell-EP) have copies of a cache line. When a request arrives at the home node, the directory cache is checked. If it contains an entry for the requested line, snoops are sent as indicated by the directory cache. If the request misses in the directory cache, the HA fetches from the address in memory and reads the directory bits and sends snoops accordingly if it is modified in some socket, or directly sends the data it fetched from memory if no snoops are required and doesn't allocate an entry. [3]
The E7 v2 HA implements a 128-entry In flight Memory Buffer (Home tracker), a 512-entry Tracker (Backup Tracker). All home channel messages incoming to the HA will go through the BT (if the BT is enabled). The BT maintains a set of FIFOs to order the requests that are waiting to get into the HT such that the HT entry is allocated to the oldest waiting request when it becomes available. It also has a Home Agent Data Buffer (a set of data buffers for transferring the data between the ring and memory controller. It has 128 entries, one for each Home Tracker). The HA needs to decode the appropriate DRAM channel from the address. This process is called “Target Address Decode”. The TAD rules for each HA would be configurable via CSRs; the rules consist of a memory range to match and then an interleave mode i.e. addr[8:6] of the truncated address to index into a list of DRAM channels. Because the TAD contains an address range to match it allows for memory reclaim for I/O-decoder stolen ranges: configure SAD DRAM decoder to decode a certain reclaim range and configure it in a TAD entry. (Workstation CPUs use TOLUD and REMAPBASE etc; the setting of these registers would change the Cbo decoders which read from them). After the target channel is decoded the request is forward to corresponding BGF (bubble generator fifo). On a read, the data will be returned from the iMC and is forwarded to the HADB. On a write, the data will be downloaded from the ring to the HADB and is forwarded to the iMC. The iMC on the server processors connects to 2 SMI2 ports per socket for riser cards with usually 12 DIMMs and a scalable memory buffer (e.g. Jordan Creek). The HA sends the data back to the requesting CBo ID + NodeID.
No Match
If an address is not matched by any range, or matches an address hole (non-existent memory attribute), the target defaults to the socket's Ubox, and the message is encoded as a NcRdPtl or NcWrPtl opcode with zero length or all zero byte enables, respectively. The Ubox treats the message as an error; errors can be configured to return an error response, or normal completion (returning data of all ones for reads or preventing data update for writes), with or without an MCA. This mechanism is used to prevent any illegal access from being routed externally during some initialisation sequences. 7500 series caching agent will not issue a MCA on access to a SAD address region marked as Non Existent Memory (NXM), unless the access is a store with write-back (WB) memory attribute.
The bus numbering on classic PCIe switch diagrams is very wrong. My GPU is in fact on bus 1 (as it's on a PCIe port). It appears that the integrated PCIe switches are invisible to software and the port just appears as a single PCIe controller / PCI-to-PCI bridge on bus 0 and the device connected to the port point to point appears on a new bus no (The Ethernet controller on bus 2 and the WLAN controller on bus 3).
In reality, PCI-to-PCI bridge 1 can't exist because it requires a subordinate bus no that isn't present on my system. Either it doesn't exist on my system and has 2 integrated PCI-to-PCI bridges like this:
Or it does exist, but has registers invisible to the programmer which change based on the content of the subordinate PCI-to-PCI bridges and the subordinate bus no would have to be 0 (rather than 1 in the diagram) (which won't mess up routing by having 2 bus numbers the same, because the interface the opposite side would not be bus 0, but directly connected to PCH logic, so a transaction will always appear to the devices to originate from PCI-to-PCI bridge 1 as if it were the root complex with nothing beyond that). That diagram presents a very misleading PCH; the PCIe interface is not as pure as that and is broken up and interfaced by the chipset where necessary (too expensive to have all the integrated PCH bridges and controllers as separate point-to-point PCIe devices on ports).
The CPU and the PCH function as single physical PCIe devices with logical subdevices. The Ubox intercepts NcCfgRd/NcCfgWr. IIO+PCH (CPUBUSNO(0)) devices can actually have a separate bus number to the core (CPUBUSNO(1)). If the bus no is CPUBUSNO(1), or CPUBUSNO(0) but below a specific device number, then it will handle the request direct. If it is on CPUBUSNO(0) and the device no is above a specific device no then it routes a Type 0 configuration TLP to the DMI interface, where any device other than logical PCI bridges respond to their function/device number (it acts like a logical bridge as if its subordinate number is that bus number, despite being on the same bus). If the bus no>CPUBUSNO(0) then it generates a Type 1 Configuration TLP on DMI, which will be absorbed by the logical bridge with that subordinate bus number.

linux netfilter pass the packet content to user space socket app

I want to write a Linux 2.6 netfilter module, which can check the incoming IP packet information, such as dest-ip, source-ip. After that pass these information to user space app which (i.e Socket app) will handle these information as soon as the packet reach the HOOKs.
I want to try two ways:
1 . Inside the netfilter module, make a fifo struct line, every time the packet reach the hook, put the packet information to the fifo. and with the help of /proc/example filesystem . every time the user space app read the /proc/example file , will get a packet information from the fifo head .
I'm a newbie of kernel program, this program crash my kernel several times. -_-!
I wonder is this way possible?
2 . Inside the netfilter module, make a char device, the user space app read packet information from this char device. But I still don't know how to make sure to get the packet as soon as possible, is there any way when the packet reach the netfilter hook, kernel will send some signal to info user space app, then the user space app come to pick the packet information?
Thank you very much.
My way of doing this:
Create a kernel module to get hooked to your network activity.
Then use Netlink which can talk to user space from the kernel to pass the data IPC.
Option 1 is possible and workable what is the problem? But I usually use to communicate between user-space and kernel space using netlink
netlink_kernel_create
netlink_kernel_release
nl_sk = netlink_kernel_create(&init_net, 17, 0, recv_cmd, NULL, THIS_MODULE);
netlink_kernel_release(nl_sk);
netlink_unicast
What do you mean by as soon as possible? Do you have some actual hard/soft realtime requirements?
If you select option 2 you should be able to get new data rather quickly by opening the character device non-blocking and select()ing on the read fd. I've done something similar with a kernel level socket, where socket data was presented to a user level process via a character driver. I saw very little latency as long as I serviced the socket in a timely manner. The driver was used in an environment that had some soft realtime requirements and we didn't have any problem meeting those requirements with run-of-the-mill kernel facilities.
Have a look at Linux Device Drivers, 3rd Edition.
I'm not sure about the first method, but using the second, your user space app could use a select() call with the char device as the only target - as soon as select() returns, you'll have data to read. Just make sure to read it all, and not just assume one packet's worth of data.