How do I fix USER FATAL MESSAGE 740? This error is generated by Nastran when I try to run a BDF/DAT file of mine.
*** USER FATAL MESSAGE 740 (RDASGN)
UNIT NUMBER 5 HAS ALREADY BEEN ASSIGNED TO THE LOGICAL NAME INPUT
USER ACTION: CHANGE THE UNIT NUMBER ON THE ASSIGN STATEMENT AND IF THE UNIT IS USED FOR
PARAM,POST,<0 THEN SPECIFY PARAM,OUNIT2 WITH THE NEW UNIT NUMBER.
AVOID USING THE FOLLOWING UNIT NUMBERS THAT ARE ASSIGNED TO SPECIAL FILES IN MSC.NASTRAN:
1 THRU 12, 14 THRU 22, 40, 50, 51, 91, 92. SEE THE MSC.NASTRAN INSTALLATIONS/OPERATIONS
GUIDE SECTION ON MAKING FILE ASSIGNMENTS OR MSC.NASTRAN QUICK REFERENCE GUIDE ON
ASSIGN PHYSICAL FILE FOR REFERENCE.
Below is the head of my BDF file.
assign userfile='SUB1_PLATE.csv', status=UNKNOWN, form=formatted, unit=52
SOL 200
CEND
ECHO = NONE
DESOBJ(MIN) = 35
set 30=1008,1007,1015,1016
DESMOD=SUB1_PLATE
SUBCASE 1
$! Subcase name : DefaultLoadCase
$LBCSET SUBCASE1 DefaultLbcSet
ANALYSIS = STATICS
SPC = 1
LOAD = 6
DESSUB = 99
DISPLACEMENT(SORT1,PLOT,REAL)=ALL
STRESS(SORT1,PLOT,VONMISES,CORNER)=ALL
BEGIN BULK
param,xyunit,52
[...]
ENDDATA
Below is the solution
Correct
assign userfile='SUB1_PLAT.csv', status=UNKNOWN, form=formatted, unit=52
I shortened the name of CSV file to SUB1_PLAT.csv. This reduced the length of the line to 72 characters.
Incorrect
assign userfile='SUB1_PLATE.csv', status=UNKNOWN, form=formatted, unit=52
The file management section is limited to 72 characters, spaces included. The incorrect line stretches 73 characters. The nastran reader ignores the 73rd character and on. Instead of reading "unit=52" the reader reads "unit=5" which triggers the error.
|<--------------------- 72 Characters -------------------------------->||<- Characters are ignored truncated ->
assign userfile='SUB1_PLATE.csv', status=UNKNOWN, form=formatted, unit=52
References
MSC Nastran Reference Guide
The records of the first four sections are input in free-field format
and only columns 1 through 72 are used for data. Any information in
columns 73 through 80 may appear in the printed echo, but will not be
used by the program. If the last character in a record is a comma,
then the record is continued to the next record.
Related
I have a structure MF file that I'm now trying to import into SAS. The fixed portion of the record is working, but when I hit the Days line the column pointer is at 30. The variable is at 15. How did the column pointer jump to 30 vs my expected value and how can I update the below.
data test;
INFILE file1 recfm=N;
INPUT seqno s370fPD9.
type $ebcdic2.
record_type $ebcdic1.
occurs s370fPD2.
#;
ARRAY Day{60} Day1-Day60;
ARRAY AMT{60} AMT1-AMT60;
ARRAY CRED{60} CRED1-CRED60;
ARRAY PAY{60} PAY1-PAY60;
DO I = 1 TO OCCURS;
input Days{I} s370fPD2.
AMT{I} s370fPD6. +2
CRED{I} s370fPD6. +2
PAY{I} s370fPD8. #;
end;
run;
I get the following in the log. While there isn't a note for Amt1, it is not populated correctly:
NOTE: INVALID DATA for Days1 at byte position 30-31.
NOTE: INVALID DATA for CRED1 at byte position 52-57.
NOTE: INVALID DATA for PAY1 at byte position 70-71.
For the first record, days1 should be at 15. Cred1 at 25 Pay1 at 33.
From replacement data table (below on the image), I am trying to incorporate the solbox product replace in time series data format(above on the image). I need to extract out the number of consumers per day from the information.
What I need to find out:
On a specific date, which number of solbox product was active
On a specific date, which number of solbox product (which was a consumer) was active
I have used this line of code in excel but cannot implement this on python properly.
=SUMPRODUCT((Record_Solbox_Replacement!$O$2:$O$1367 = "consumer") * (A475>=Record_Solbox_Replacement!$L$2:$L$1367)*(A475<Record_Solbox_Replacement!$M$2:$M$1367))
I tried in python -
timebase_df['date'] = pd.date_range(start = replace_table_df['solbox_started'].min(), end = replace_table_df['solbox_started'].max(), freq = frequency)
timebase_df['date_unix'] = timebase_df['date'].astype(np.int64) // 10**9
timebase_df['no_of_solboxes'] = ((timebase_df['date_unix']>=replace_table_df['started'].to_numpy()) & (timebase_df['date_unix'] < replace_table_df['ended'].to_numpy() & replace_table_df['customer_type'] == 'customer']))
ERROR:
~\Anaconda3\Anaconda4\lib\site-packages\pandas\core\ops\array_ops.py in comparison_op(left, right, op)
232 # The ambiguous case is object-dtype. See GH#27803
233 if len(lvalues) != len(rvalues):
--> 234 raise ValueError("Lengths must match to compare")
235
236 if should_extension_dispatch(lvalues, rvalues):
ValueError: Lengths must match to compare
Can someone help me please? I can explain in comment section if I have missed something.
I run this code
cmd := exec.Command(sArg[0], sArg[1:]...)
d, err := cmd.Output()
if len(arg) == 0 {
return err
}
file.WriteString(string(d))
After running it, the string is printed well in the debugging console, but the character is broken in the file.
Original Output
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\SharedAccess\Parameters\FirewallPolicy\StandardProfile
DisableNotifications REG_DWORD 0x0
EnableFirewall REG_DWORD 0x1
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\SharedAccess\Parameters\FirewallPolicy\StandardProfile\Logging
Broken Output in File
How can characters be correctly written to a file?
If I take 0d, 0a, 48, 4b, 45, 59, 4b, 4c, 4f, 43, 41, 4c, 5f, 4d, 61 43, 48 and assume it's encoded using UTF-16-LE this will be displayed as 䭈奅䱋䍏䱁䵟䍡 which looks about the same as the first section of your screenshot. As such it appears to me that your program is saving the data correctly but the application you are using to view the file is incorrectly interpreting it as UTF-16-LE encoded.
It is possible that this is due to whatever you wrote to the file previously (you mention that this data is being appended to data written earlier). If the first two bytes are FF, FE this can be taken as a signal that the file is UTF-16-LE encoded but not all editors will recognise this).
If you open the file in a hex editor I expect that you will see the data as expected (i.e. 0d, 0a, 48,...).
I am reading large files in Fortran that contain mixed string/numeric data such as:
114 MIDSIDE 0 0 O0002 436 437 584 438
115 SURFACE M00002 0 0 359 561 560 356
412236 SOLID M00002 O00001 0 86157 82419 82418 79009
Currently, each line is read as a string and then post-processed to identify the proper terms. I was wondering if there is any way to read each line as an integer followed by four strings separated by space, and then some more integers; i.e. similar to '(I10,4(A6,X),4I10)' format, but without any information on the size of each string.
Does not work (charr is empty, iarr(2:5)=0):
INTEGER IARR(5)
CHARACTER*30 CHARR(4)
C open the file with ID=1
READ(1,*)IARR(1),(CHARR(I),I=1,4),(IARR(I),I=2,5)
Works (only for the last line in the data example):
INTEGER IARR(5)
CHARACTER*30 CHARR(4)
C open the file with ID=1
READ(1,'(I10,4(A7,X),4I10)')IARR(1),(CHARR(I),I=1,4),(IARR(I),I=2,5)
The issue is I don't know a-priori what would be the size of each string.
I actually found out the f77rtl flag was used to compile the project, and when I removed the flag, the issue was resolved. So the list-directed input format works just fine.
What command would give me the output I need for each instance of an error code in a very large log file? The file has records marked by a begin and end with number of characters. Such as:
SR 120
1414760452 0 1 Fri Oct 31 13:00:52 2014 2218714 4
GROVEMR2 scn
../SrxParamIF.m 284
New Exam Started
EN 120
The 5th field is the error code, 2218714 in previous example.
I thought of just grep'ing for the error code and outputting -A lines afterwards; then picking what I needed from that rather than parsing the entire file. That seems easy but my grep/awk/sed usage isn't to that level.
ONLY when error 2274021 is encountered as in the following example I'd like some output as shown.
Show me output such as: egrep ‘Coil:|Connector:|Channels faulted:| First channel:’ ERRORLOG|less
Part of input file of interest:
Mon Nov 24 13:43:37 2014 2274021 1
AWHMRGE3T NSP
SCP:RfHubCanHWO::RfBias 4101
^MException Class: Unknown Severity: Unknown
Function: RF: RF Bias
PSD: VIBRANT Coil: Breast SMI Scan: 1106/14
Coil Fault - Short Circuit
A multicoil bias fault was detected.
.
Connector: Port 1 (P1)
Channels faulted: 0x200
First channel: 10 of 32, counting from 1
Fault value: -2499 mV, Channel: 10->
Output:
Coil: Breast SMI
Connector: Port 1 (P1)
Channels faulted: 0x200
First channel: 10 of 32, counting from 1
Thanks in advance for any pointers!
Try the following (with the convenient adaptations)
#!/usr/bin/perl
use strict;
$/="\nEN "; # register separated by "\nEN "
my $error=2274021; # the error!
while(<>){ # for all registers
next unless /\b$error\b/; # ignore unless error
for my $line ( split(/\n/,$_)){
print "$line\n" if ($line =~ /Coil:|Connector:|Channels faulted:|First channel:/);
}
print "====\n"
}
Is this what you need?