The scope in simulink drops first few data - scope

I have a simulation set to run for 30 seconds, with several scopes. The problem is that the output for the first 20 seconds of the run is dropped by the scopes at the end of the simulation run.
If I want to see these outputs, I would have to change the 'stop time' in configuration parameters to 20 seconds. My 'start time' is always set at 0.0 seconds.
Is there any place where I can change the buffer setting or something?

By default, the scope block will only display the last 5000 data points. As described in the doc for the scope block, you can adjust this setting by navigating to the History tab of the scope's parameters dialog box. There you will see the setting Limit data points to last. You can either increase the number of data points that are displayed, or simply uncheck this setting to allow all data points to be displayed. Because you are running your simulation over such a short span of time, it's probably perfectly fine to just uncheck this setting on each of your scopes.

Related

Can a SharePoint "Delay" action be resetted using a variable while its active?

Im creating a workflow for approvals using power automate. I also have this reminder system set up to remind them every hour for 4 times and then once a day afterwards. This works when I have a parallel task set up, but for this specific loop in the approval, im using apply to each since i can add as many people to review myd ocument as I want. I notice that I can't reset the delay action while its active because it is still running. The only way it gets reset is that the delay action is finished and starts the loop again and then the variable gets reset.
This works if the loop isnt inside an apply to each and the reminder system works as well.
enter image description here

is there a function that conditions the rest of the script

I use with imacro and chrome a macro to make clicks at a specific location on a web page, with the loop function and the good timing of 2:10 it restarts correctly... 99 times, but what I'm looking for is a command line that launches the rest of the macro (the clicks have a precise location already defined) only if the value of a specific field of the web page is equal to 0, otherwise it remains on hold then rechecks so on... It's possible ? thank you in advance
Automatically launch the rest of the macro if the value is 0, otherwise wait and check regularly

DataSource.Error AnalysisServices: The XML for Analysis request timed out before it was completed.Timeout value:3600 sec

After connecting to analysis server through excel,when I am trying to import complete data into excel getting error after being loaded few rows.
Try changing the ServerTimeout server property to a value high enough for this operation to complete. To do this, connect to the SSAS server through SSMS and right-click the instance name then select Properties. Go the the General Tab, check the Show Advanced (All) Properties checkbox and find the ServerTimeout property. This is set in seconds with the a default of 3600 (one hour) as seen in the error message. Modify the Value column to be high enough to finish this task. After changing the ServerTimeout property press OK and this will be effective immediately with no restart necessary. For more details on this and other SSAS properties review the documentation. If what you're importing into Excel typically takes longer than an hour, you may want to look into another means of performing this such as SSIS.

calculate load time repeat control

Under a repeat control I would like to display a message how long it took to load the data-set for it e.g. "1000 documents loaded in 0.2 seconds".
How can I do this?
The number of elements in the list is easy via getRowCount(). But how can I get the time to collect the data?
You can put the start value in a scoped variable in the BeforePageLoad event and then access it after the page has loaded. You could use
System.nanoTime
for both values

How can I adjust the ExpressionEngine search rate limit?

I have added a search functionality to my ExpressionEngine site, using the standard Search Module tags. However, I occasionally run into this error message:
You are only allowed to search every 15 seconds.
This only seems to happen when I'm logged out.
I want to decrease the time required between searches. How can I adjust this?
It's a per-group setting (hence why it's only happening when you're logged out). The default for logged out members (the Guests group) is 15 seconds.
You can adjust this value for each group under Members > Member Groups > Edit Group in the control panel.

Resources