Snipe-IT on IIS - iis

Is it possible to install snipe-it application using php 8.0? Everything I see says php 7.4 but I want to use 8.0 and am getting a 500 internal server error on my Windows 2019 server VM. Is there something I am missing or need to added in order to get the installation working correctly?
It appears I keep getting different 500 errors via web browser.

Related

Url rewrite 2.1 stops Application pool in IIS 8.5 (return 503 status), windows server 2012R2

I install the URL Rewrite from the Web Platform Installer.
No added rule.
Then, when I access website url, it returned 503 code and Application Pool was stopped.
It works normally when I uninstall the URL rewrite module from Control Panel.
I have tried many searches on google but no results.
I found that in Event log:
- The Module DLL C:\Windows\system32\inetsrv\rewrite.dll failed to load. The data is the error. Application pool 'DefaultAppPool' is being automatically disabled due to a series of failures in the process(es) serving that application pool.
(rewrite.dll is exits)
Any ideas?
In event log I found the same message. I.e. The Module DLL C:\Windows\system32\inetsrv\rewrite.dll failed to load. The data is the error.
For me the solution that worked was to replace the "rewrite.dll". In 2 of our other server it was working fine and they were installed in 2017. So I just copied the "rewrite.dll" from that server and replace it on my new server.
For me the older version(v7.1.1952.0) of the dll works, but new version ( v7.1.1993.2351), which comes with the latest setup, doesn't work.
BTW you need to stop the IIS before you replace the dll and start again.
I had the same experience and nothing I did fixed the issue e.g. repair, reinstall, restart, etc.
Then I removed what the Web Platform Installer installed and manually installed the x64 version of URL Rewrite and everything now works nicely.
Make sure what you’re installing matches the OS.

Getting error 404 while using Alteryx Gallery default URL

I have installed Alteryx server in my Windows based 2008 R2 server But I am not able to use default Gallery Url http://localhost/gallery/
getting error code-404
The server may not be started, it starts manually after the initial install at times; check in services.msc to see if the Alteryx Service is running.

Windows 10 ERR_SSL_PROTOCOL_ERROR when enabling SSL

My office just gave me a new machine with Windows 10 and both VS2013 and VS2015 installed. I transferred an existing VS2013 project to the machine, but when I attempt to run, I get a ERR_SSL_PROTOCOL_ERROR error in Chrome. There doesn't appear to be a Repair IIS Express application in Win10. I considered uninstalling IIS Express 10 and install 8, but I'd need to get permission for that and it wouldn't be an easy sell. What else can I look at?
I couldn't find a solution anywhere online that would help me out until I removed the bindings that I was trying to access via the IIS site bindings in IIS manager - see below :
This was the only binding I kept - I removed the other bindings which were pointed at the ports that I needed.

IIS 7.5 Detailed Error 500.0 - Internal Server Error occurred after enabling ServersideInclude with Windows 7 IIS 8 Express

I have ServerSideIncludeModule enabled using "Turn on/off Windows Features" Control Panel. On inetmgr's Handlers-Mapping suite, I have mapped it to handle my .html extension.
However after everything has been done and I tried to browse my Default.html (which has
<!--#include virtual="includes/NavBand.html"-->
) it gave me the above 500.0 - Internal Server Error on this url
http://localhost/myDir/Default.html
!!
If I removed my mapping, my default page works again of course without the include htmls.
I have checked the Permission, the users have read and script rights.
However, the same implementations work fine on Windows Server 2008 IIS7.5 just not on my local workstation which has IIS installed on it.
Remarks: There is a file NavBand.html sitting inside the .\includes dir. So that is not the issue.

Setting up Coldfusion 10 with IIS - Unable to configure IIS connector

I'm trying to setup Coldfusion to work with IIS on my Windows 8 laptop. I have installed the ISAP filter and extensions along with the CGI extension but when I run the wsconfig and add the web server it then throws the error "Unable to configure IIS Connector". What can I try next? I've made sure they're all enabled in the IIS manager also.
The coldfusion 8 webserver configuration tool states that it is compatible until IIS 7. This is probably why it fails to add the handler mappings for IIS 8.
I found that by uninstalling coldfusion and re installing worked, that way in the setup it was able to identify what web servers were currently running and give me the option to configure coldfusion with IIS. Hope this helps someone else too

Resources